MLSD low-voltage fixed partitioned switch cabinet
MLS-type withdrawable low-voltage switchgear is a low-voltage switchgear designed and produced by our company with the introduction of foreign advanced technology, while MLSD-type fixed and separated low-voltage switchgear is a fixed and separated low-voltage switchgear with domestic advanced level developed on the basis of MLS according to the particularity and applicability of power distribution scheme. MLS/MLSD adopts advanced design concept and manufacturing technology, and has the characteristics of safety, reliability, economy and environmental protection. It is suitable for power supply systems with AC 50~60H rated working power music 690V and below. Such as: power plants, substations, industrial and mining enterprises, buildings, residential, transportation, etc. as power distribution, motor and electrical equipment control, lighting, power conversion, power compensation.
- Product Description
- Technical features
- Main technical parameters
-
- Commodity name: MLSD low-voltage fixed partitioned switch cabinet
MLS-type withdrawable low-voltage switchgear is a low-voltage switchgear designed and produced by our company with the introduction of foreign advanced technology, while MLSD-type fixed and separated low-voltage switchgear is a fixed and separated low-voltage switchgear with domestic advanced level developed on the basis of MLS according to the particularity and applicability of power distribution scheme. MLS/MLSD adopts advanced design concept and manufacturing technology, and has the characteristics of safety, reliability, economy and environmental protection. It is suitable for power supply systems with AC 50~60H rated working power music 690V and below. Such as: power plants, substations, industrial and mining enterprises, buildings, residential, transportation, etc. as power distribution, motor and electrical equipment control, lighting, power conversion, power compensation.
-
The frame structure used is highly flexible, and once the structure is assembled, maintenance is no longer required. Different standard components can be installed in the cabinet to meet various use requirements.
The design of the system and the materials used can prevent the occurrence of fault arc to the greatest extent. Once the fault occurs, the arc can be extinguished in a short time. -
Rated insulation voltage of main circuit AC 660V, WOOV Rated operating voltage of main circuit AC 380V, 660V Rated frequency 50Hz/60Hz Rated operating current of busbar Horizontal bus (main bus) After the horizontal bus is placed in the cabinet: 630, 800. 1000. 1250. 1600.2000, 2500, 3200, 4000 and 6300 Horizontal busbar cabinet top: 630, 800, IOO0, 1250, 1600, 2000, 2500, 3200, 4000, 6300 Vertical bus (branch bus) L-type vertical bus: 1200, 2000A Rectangular vertical bus: 630-1600A (only for horizontal bus on cabinet top) Rated short-time withstand current (IS) Horizontal bus (main bus):50, 80kA Vertical bus (branch bus):50kA Protective conductor (grounding main bus):30, 48kA Neutral bus (neutral main bus):30, 48kA Rated peak withstand current Horizontal bus (main bus):105, 176kA Vertical bus (branch bus):105kA Protection level IP4X、IP3X