The SID3000 distribution network automation terminal is mainly an intelligent distribution terminal designed for the distribution network automation system, which is suitable for the comprehensive monitoring of multi-circuit lines such as switching stations and ring network cabinets. It has the advantages of integration, integration and scalability. It can monitor 12 lines at the same time, and analyze and process the real-time data of 12 lines at the same time. SID3000, each monitored line is equipped with functions such as two-stage interphase overcurrent protection, overload protection, zero-sequence overcurrent protection, and multiple reclosing protection, which can automatically remove faulty lines.
- Product Description
- Technical features
- Main technical parameters
-
- Commodity name: Distribution Automation Terminal (DTU)
The SID3000 distribution network automation terminal is mainly an intelligent distribution terminal designed for the distribution network automation system, which is suitable for the comprehensive monitoring of multi-circuit lines such as switching stations and ring network cabinets. It has the advantages of integration, integration and scalability. It can monitor 12 lines at the same time, and analyze and process the real-time data of 12 lines at the same time. SID3000, each monitored line is equipped with functions such as two-stage interphase overcurrent protection, overload protection, zero-sequence overcurrent protection, and multiple reclosing protection, which can automatically remove faulty lines.
-
- The whole machine has low power consumption, modular software design, and perfect protection function configuration.
- The standard 4U aluminum alloy chassis structure, front plug-in design, production, installation and maintenance is convenient, very suitable for the special installation requirements of the distribution network.
- The main control, telemetry, remote control, remote communication and power supply boards are independent of each other and adopt modular design, which can be matched at will. The upgrade and expansion of various modules are convenient and will not be affected by each other.
- Centralized operation can simultaneously monitor 4 sections of bus and 12 circuits, perform real-time data processing on all monitored objects, monitor current and voltage imbalance, effectively remove faulty lines, and reduce power failure range. Under the double-layer structure, it can effectively monitor the operation status of the 24-circuit line.
- Large-capacity non-volatile memory holds a variety of records and data, including protection events, remote shift SOE, daily extremes, telemetry data whole point records, and so on. The storage capacity of all records and data shall not be less than 30 days.
- Two-level watchdog protection and dynamic self-test function ensure the working reliability of the device.
- Each line is equipped with four sets of fixed value, which can easily switch different fixed value groups according to different working conditions of the line. Remote/local modification of fixed values and parameters is supported.
- It has two Ethernet interfaces and four RS232/RS485 communication interfaces. Optional external GPRS/CDMA communication module.
- Support CDT, DNP3.0, 101, 103, 104 and other communication protocols.
-
Technical terms Technical parameters Working environment Operating temperature:-40% ~ + 70%; Relative humidity: 5% ~ 95%; Altitude: W 3500m; Rated data AC voltage: 100V; AC current: 5A or 1A; Frequency: 50Hz; Power supply: AC220V/110V, ±20%; DC220V/110V/48V/24V ±20% Overload capacity Long-term operation of the voltage circuit- ----- 1.5 ×Un; Long-term operation of current loop I -----In; Power consumption Power supply power is not greater than IoW The AC flow input circuit is not more than 0 ∙ 5VA/circuit Voltage 0-1.5 XUn Measurement range Current 0 - 2 ×In Zero sequence current O-IOA (secondary value) Voltage <0.5% Current <0.5% zero sequence current <0.005A Power, power factor <0.5% Frequency <0.01 HZ Voltage and current unbalance rate <0.5% Open-in loop Active contact input, current consumption 2mA open contact AC 220V, 5A